Home » Gas Detectors » Find by Application » BW MicroDock II Automated Gas Detector Docking Station
BW MicroDock II Automated Gas Detector Docking Station





Each base station can manage up to 10 different detectors in their own attached docked module, six of which can have charging built in. Supported products are:
- GasAlertMicroClip
- GasAlert Quattro
- GasAlertMax XT
- GasAlertMicro 5 (including PID and IR models)
- GasAlertClip Extreme (including 24 months and 36 months models)
- GasAlert Extreme
MicroDock saves valuable time and money by automating manual procedures. In addition, the MicroDock II ensures compliance - calibration and bump testing is done automatically with event logging and alarm set point verfication.
The MicroDock automates a number of important functions:
- Automatic bump testing of detectors
- Automatic calibration of detectors
- Automated management of event logs, calibration logs, etc
- Automated verification of alarm set points
MicroDock II includes reporting software so that accurate records can be kept for each detector. Multiple stations can be networked together with a LAN/USB bridge.
NOTE: MicroDock II is a highly configurable product. Please call for pricing and part numbers. Calibration gas is sold separately. Each calibration gas requires its own gas flow regulator.
The Bad:
The Bottom Line:
Full Review
- Fully automatic “hands-free” calibration & functional bump test
- Automatically verifies performance of audible and visual alarms
- Stores and updates calibration records in the MicroDock II, as well as in the GasAlertMicro 5, GasAlertMicro 5 PID, GasAlertMicro, GasAlertMicroClip and GasAlert Extreme detectors
- No computer required
- Entirely self-contained
- Fully portable
- Lightweight and mobile
- Operates via line power or a set of four C-cell batteries
- Add additional self-contained docking modules to system via simple, plug-in connections-no external pressure transducers or gas lines necessary
- Simplify record keeping
- Verify proper performance
- Reduce maintenance costs
- Multiple MicroDock II systems can be connected via a LAN
- Multi-language support in English, French, German, Spanish, and Portuguese
|
INSTRUMENT |
Automated calibration/bump-test
station for GasAlertMicro 5, GasAlertMicro 5 PID, GasAlertMicro,
GasAlertMicroClip, GasAlert Extreme, and GasAlertClip Extreme family |
|
GENERAL SPECIFICATIONS |
|
|
Microcontroller |
High performance microcontroller
system |
|
Power supply |
6V wall adapter or four C-cell
batteries |
|
Real-time clock |
Provides time and date stamp for “last
calibration” and “last bump” data |
|
Data storage |
Automatic (instrument and base
station) 64
MB MultiMediaCard data storage system |
|
External interface |
USB 2.0 interface for PC (USB 2.0
full speed) |
|
Pump |
DC motor, micro-diaphragm; 3.3V
PCB mount |
|
Flow rate |
Typically 300 mL/min |
|
Calibration gas cylinder inputs |
2-gas inlets (standard) 5-gas inlets (maximum) |
|
Automatic tests |
Functional bump, calibration,
audible alarm, visual alarm |
|
Configuration recognition |
Automatic (instrument and sensor) |
|
Detector configuration |
User-settable with Fleet Manager
applications |
|
Calibration gas connections |
Built-in (base station) 1/8” SMC connect sub-miniature
coupling |
|
Solenoid |
Built-in (docking modules) |
|
LED Indicators |
Yellow - TEST |
|
(on each docking module) |
Green - PASS |
|
|
Red - FAIL |
|
LCD |
4 line x 16 characters, wide
viewing angle, user-selectable backlighting |
|
Physical size |
8.3 x 10.4 x 3.2 in. / 21.2 x 26.3
x 8.2 cm (base station plus one docking module) |
|
Enclosure |
Impact- resistant PC/ABS
(polycarbonate) |
|
COMMAND KEYS |
|
|
Base station |
Menu navigation |
|
Docking modules |
One touch Bump-test initiation |
|
|
One touch Calibration intitation |
|
Communications method |
Infrared communication between
docking module and detector |
|
WARRANTY |
2 years |
Data storage and analysis has never been so simple. With the same look and feel as Fleet Manager, Fleet Manager II allows users to download information directly from BW instruments or the MicroDock II.
With improved functionality, users can:
• Automatically create accurate and user-friendly reports
• Easily sort, format and graph data as well as view history
• Archive and share data easily, including databases
• Download and manage calibration and bump check records as well as datalogged information onto any PC
Compatible with:
- GasAlertQuattro
- GasalertMax XT
- GasAlertClip Extreme 24 Month
- GasAlertClip Extreme 36 Month
- GasAlert Extreme
- GasAlertMicro
- GasAlertMicro 5 Series (Micro 5 IR, Micro 5 PID)
- GasAlertMicroClip
- MicroDock II

-150x150.jpg)