BW Honeywell BWC4-Y-N Clip4 4-Gas Detector (O2, LEL, H2S, CO), Yellow-

Downloads: datasheet

BW Honeywell BWC4-Y-N Clip4 4-Gas Detector (O2, LEL, H2S, CO), Yellow

Model: BWC4-Y-N

This unit stays on to keep you safe and clips easily to your clothing. 2 years without charging or battery replacement needed. Can detect Hydrogen Sulfide (H2S), Carbon Monoxide (CO), Oxygen (O2) and Combustible Gases (LEL).

Sale Price $493.75 USD
Regular Price $625.00 USD
Availability 5 in Stock
Quantity

Honeywell Clip4 Offers

Easy to Wear

  • Durable, ergonomic and wearable — doesn't weigh you down
  • Compact profile — even working in tight spaces, you won't know you are wearing it

Easy to Use

  • Simple one-button operation
  • User-friendly tamper-proof operation with just one button
  • Intuitive LCD icons
  • Real-time gas concentrations shown on LCD

Easy Compliance

  • Flashing red non-compliance indicators warn workers that the detector has not been bump tested according to schedule
  • Daily full function self-test of sensors, battery status, circuit integrity, and audible/visual alarms

Easy to Manage

  • Compatible with IntelliDoX docking system and instrument management system

Easy to Rely On

  • Built-in concussion proof boot
  • Tested to last in extreme environments

BW BWC4-Y-N Specifications

Size 4.7 x 2.7 x 1.3 in. / 11.9 x 6.8 x 3.2 cm
Weight 8.2 oz. / 233 g
Warranty Full two year warranty including all sensors
Click here for complete specifications on the BW BWC4-Y-N

How to Select the Right Gas Detection Solution

by Don Galman

There are many gas detection products on the market that might appear to be the same, but a closer inspection of specification, functionality and features reveals major differences in what products can do and the potential value they can offer. Similarly, individual applications are also unique in their respective designs, needs and processes undertaken.

Know your site risks

Before beginning to consider gas detection equipment, a risk assessment needs to be conducted. Any company employing staff has the obligation to conduct risk assessments to identify potential hazards and these can include potential gas, vapor or Oxygen deficiency risks. If gas hazards are identified, gas detection is applicable as a risk reduction method.

Identifying the prime objective

Depending on the processes being undertaken and the gases being detected, remote or off-site alarm notification plus event data logging/reporting may also be required for Health and Safety management records. Another factor impacting on the need for enhanced reporting functions might be regulatory compliance or a condition of insurance.

Ask the right questions

Having identified the primary objective, the suitable equipment is selected by asking a number of key questions. These fall into three broad categories:

  • The gases to be detected and where they may come from
  • The location and environmental conditions where detection is to take place
  • The ease of use for operators and routine servicing personnel
Identify the gases to be detected and where they may come from

The gases to be detected should be identified by the risk assessment, however experienced gas detection equipment manufacturers and their approved distributors are often able to help in this process, based on their experience of similar applications. However, it is important to remember that it is the end-user’s responsibility to identify all potential hazards. It is also essential to identify the potential source of a gas release as this helps determine the number and location of detectors required for a fixed gas detection system.

Consider the environmental conditions

The performance, accuracy and reliability of any gas detection equipment will be affected by the environmental conditions it is subjected to. Temperature, humidity and pressure levels at the location all have a direct bearing on the type of equipment that should be selected. Additional factors such as potential variations resulting from a production process itself, diurnal/nocturnal fluctuations and seasonal changes may also affect the type of device which is suitable.

Understand product functionality

The next area of consideration relates to additional product functionality. Aspects like wiring configuration are important, especially when retro-fitting into an existing application. If the apparatus is being integrated into a separate safety system, certain communication protocols may also be required such as HART®, Lonworks or Modbus®. Consideration will also need to be given regarding the requirement for local displays on transmitter units and local configuration of the unit and gas displays may also be a useful addition.

Measure the ease of use for operators and routine servicing personnel

Routine maintenance is another important consideration. Some gases and vapors can be detected with a number of different sensing technologies, e.g. Hydrocarbon gases with catalytic beads or Non-dispersive Infrared NDIR. Catalytic beads do not provide fail-to-safety operation and therefore can require a high frequency of routine maintenance, however NDIR based solutions tend to have a higher initial purchase price, but may require less routine maintenance. In-house resource to undertake such routine maintenance needs to be identified and in the absence of such a resource, budgeting for third party maintenance is an important factor in selecting the right equipment.


Need Help Selecting the Right Solution?

If you have questions about any of our gas detection products or services, please don’t hesitate to contact us. Whether you need a hand finding a new product or need help with your current system, just ask our team of Factory Trained Experts.


comments powered by Disqus

What's included with the BW BWC4-Y-N

  • BW Honeywell BWC4-Y-N Clip4 4-Gas Detector (O2, LEL, H2S, CO), Yellow
  • BW Clip4 Always On 4-Gas Detector

    How to: Calibrate a BW Gas Detector

    How to: Bump Test a BW Gas Detector

    Meet Shauna Park: Our Gas Detection Expert

    Click on a category to view a selection of compatible accessories with the BW Honeywell BWC4-Y-N Clip4 4-Gas Detector (O2, LEL, H2S, CO), Yellow.

    -
    BW REG-0.5 Calibration Gas Regulator for GasAlert, 0.5 LPM, Male REG-0.5
    Calibration gas regulator at 0.5 LPM for all GasAlert gas detectors. Regulators are used to ensure you receive the required flow of calibration gas for your application.




    -
    BW MK-CG2-58 Wall Mount for 34, 58, 103 L Gas Cylinders, Red MK-CG2-58
    Note: Gas cylinder not included




    -
    BW CG-Q58-4 Quad Gas Calibration Gas, CH4, O2, H2S, CO, 58L CG-Q58-4
    CH4 (2.5%), O2 (18.0%), H2S (25 ppm), and CO (100 ppm) gas contained within a 58L, aluminum cylinder. Fully compatible with BW Technologies gas detectors requiring specified cal gas mixture.




    -
    BW CG-Q34-4 Quad Gas Calibration Gas, CH4, O2, H2S, CO, 34L CG-Q34-4
    CH4 (2.5%), O2 (18.0%), H2S (25 ppm), and CO (100 ppm) gas contained within a 34L, aluminum cylinder. Fully compatible with BW Technologies gas detectors requiring specified cal gas mixture.




    -
    BW C2-HOSE1-1 Calibration Hose, Tygon, 1ft (0.3m) C2-HOSE1-1
    Tygon calibration hose (1ft. / 0.3m)




    -
    BW REG-DF-1 Demand Flow Regulator for GasAlert REG-DF-1
    Demand flow regulator for all GasAlert gas detectors. Demand flow regulators are recommended since they deliver the required gas flow rate automatically. Demand flow regulators must be used with gas detectors with internal or external sample draw pumps.






    -
    BW GA-CH-2 Chest Harness for GasAlert GA-CH-2
    For use with GasAlert gas detectors.
    Note: Unit not included.




    -
    BW GA-LY-1 Short Strap for GasAlert, 6in (15.2cm) GA-LY-1
    The short strap (6 in. / 15.2 cm) facilitates the attachment of your gas detector to your clothing or personal protective equipment (PPE). The smaller loop attaches to buttons or other fasteners.




    -
    Honeywell DX-BWC4 IntelliDoX Docking Station for the Clip4 DX-BWC4
    IntelliDoX makes the Clip4 the most flexible, configurable maintenance-free detector on the market, helping you improve safety, reliability and productivity in gas detection. Combining smart docking modules and Fleet Manager II software, the system helps you drive productivity, reliability and efficiency.




    -
    BW DX-ENBL-NA IntelliDox Enabler Kit for the BW IntelliDoX DX-ENBL-NA
    One Enabler Kit is needed for each stand-alone IntelliDoX module or up to 5 connected modules.




    -
    BW D4-AS01 Manual Aspirator Pump Kit with Sampling Hose, 10ft/3m D4-AS01
    For use with the GasAlertMicro5
    Note: Instrument adaptors and probes are not included.




    Ask a question about BW Honeywell BWC4-Y-N Clip4 4-Gas Detector (O2, LEL, H2S, CO), Yellow

    comments powered by Disqus