This confined space kit includes one GasAlert MicroClip XT four gas monitor (LEL, O2, CO, H2S) plus IR connectivity kit, remote sampling kit, calibration gas, flow regulator, hoses, manual, training CD, and durable carry case.
This confined space kit includes one GasAlert MicroClip XT four gas monitor (LEL, O2, CO, H2S) plus IR connectivity kit, remote sampling kit, calibration gas, flow regulator, hoses, manual, training CD, and durable carry case.
Discontinued!
This product has been discontinued and is no longer available.
This is the direct replacement:
| Gas | Measuring Range | Resolution |
| H2S | 0-100 ppm | 1 ppm |
| CO | 0-500 ppm | 1 ppm |
| O2 | 0-30.0% | 0.1% |
| Combustible gases | 0-100% LEL 0-5.0% v/v | 1% 0.1% |
| Alarm setpoints for all sensors are user adjustable. Setpoints are automatically displayed during instrument start up. | ||
| Size | 4.4 x .4 x 1.1 in. / 11.3 x 6.0 x 2.9 cm |
| Weight | 6 oz. / 171 g |
| Temperature | -4 to +122F / -20 to 50C |
| Humidity | 0% - 95% RH (non-condensing) |
| Alarms | - Visual, vibrating, audible (98 dB) - Low, high, STEL, TWA, OL (over limit) |
| Tests | Audible/visual alarms on activation, sensors, battery and circuitry (continuous) |
| Pump | Compatible with the Sampler motorized sampling pump |
| Typical battery life | 10 hours (typical); recharges in less than 4 hours |
| User options | Confidence beep Set STEL interval Sensor on/off Latching alarms Safe display mode Stealth mode Calibration lock Auto zero on start up O2 auto calibration on start up Set bump test interval IntelliFlash interval Combustable gas measurement (% LEL or % by volume methane) User-settable calibration gas level Force bump test when overdue Force calibration when overdue Low alarm acknowledge Language choices (five) Set custom start up message |
| Ratings | EMI/RFI: Complies with EMC Directive 89/336/EECIP 66/67 |
| Certifications and approvals | Class I, Div. 1, Gr. A, B, C, D ATEX: II 1 G Ex ia IIC T4 Ga IECEx: Ex ia IIC T4 Ga European Conformity |
| Warranty | Full two-year warranty including all sensors |
Simplify confined space entry. BW confined space kits are designed to provide all the accessories necessary to safely sample and effectively monitor for atmospheric hazards during confined space entry work.
With a manual aspirator and a sampling probe (10ft/3m), you can remotely sample areas with your diffusion multi gas detector.
A concussion boot and holster allow you to protect the Micro Clip whilst keeping it handy (lest you forget it!).
The IR Data Link kit and Fleet Manager II software allow you to download logged data as well as access and adjust the devices settings (not accessible on the detector itself as it utilizes a simple one button interface to avoid on the job confusion or mishandling).
An auxiliary filter fits snugly within the concussion boot or holster will protect the sensors from dust and dirt so you device functions at optimal levels throughout its lifespan.
This is all contained inside a sturdy, durable foam-lined case for ease of transport and protection.
What's Included:
The MicroClip XT
The GasAlertMicroClip XT is designed to simplify multi-gas monitoring with a combination of ease of use, durability, compliance insurance, performance and affordability. The slim and compact BW GasAlert MicroClip XT provides affordable protection from atmospheric hazards. This multi-gas detector provides continuous visual confirmation of detector operation and compliance with the IntelliFlash™ feature and the simple one-button operation offers ultimate ease of use and significantly reduces time spent training. The GasAlert MicroClip XT is fully compatible with the BW MicroDock II automatic test and calibration system.