Customer Reviews

Honeywell E3SA E3Point Toxic and Combustible Gas Monitor with wall mount, analog, 24 V AC/V DC

Model: E3SA | Order No: 1309A0042

Honeywell E3SA E3Point Toxic and Combustible Gas Monitor with wall mount, analog, 24 V AC/V DC-


Downloads:

Honeywell E3SA E3Point Toxic and Combustible Gas Monitor with wall mount, analog, 24 V AC/V DC

Model: E3SA | Order No: 1309A0042

Capable of detecting a range of toxic and combustible gases found in commercial building spaces and outbuildings, this analog gas monitor features a wall mount and 24 V AC. Additionally, this is a standalone unit with dual-gas detection by using a remote sensor (sold separately) or single detection.

Capable of detecting a range of toxic and combustible gases found in commercial building spaces and outbuildings, this analog gas monitor features a wall mount and 24 V AC. Additionally, this is a standalone unit with dual-gas detection by using a remote sensor (sold separately) or single detection.

Discontinued!

This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:

Visit our Confined Space Kits category for similar products.

Or let's do a search and help you find what you need:


BW E3SA Offers

Capable of detecting CO, NO2, O2, H2, H2S, CH4, and C3H8 gases (sensors sold separately), this gas monitor that features an intelligent design to reduce the cost of ownership while increasing the flexibility of the application. In addition, this monitor can also operate with existing controller-based gas monitoring systems and wired-wireless gas monitoring system components.

Features

  • Versatile communications: Couple with 301C to log data and daisy-chain up to 96 toxic and combustible gas monitors
  • Electrical certification: Canada (CSA C22.2 No. 61010-1) and US (ANSI/UL 61010-1)
  • Ergonomic features built into this monitor include a hinged door for maintenance ease
  • Efficient operations: Smart sensor design, extreme temperature range, etc. optimize building performance
  • Energy saving: On-demand ventilation controls energy use
  • Economical value: Reduces cost of installation, operation and maintenance
  • Standalone dual-gas sensor operation: Economical application adds option of a second (remote) sensor for dual gas monitoring and two on-board relays can activate ventilation or strobes
  • Complete toxic and combustible gas detection system with onboard sounder

Reflex® keeps you safer

This patented Reflex® technology adds this extra degree of precision and diligence to sensor monitoring to make doubly sure you're safe. Reflex bounces electrical signals into this monitor's electrochemical sensor cell at regular intervals, a form of electronic bump testing and continuous monitoring of cell response.

Standalone single-sensor operation

A low-cost application for buildings with minimal gas monitoring requirements typical of a small facility. Offers easy installation, commissioning and operation. Two on-board relays can activate fan or strobe.

Plug-n-play ease

This monitors plug-n-play sensor (sold separately) is factory calibrated and works out of the box. Upon installation, this monitor automatically configures for quick operation. You benefit from easier installation and maintenance, and greater adaptability to changing building and safety requirements.

Flexible operation

  • Comes in standalone or standalone with remote (dual gas mode)
  • Connects to analog system
  • Wall mount
  • Factory-calibrated cartridges (sold separately)

Cost-effective

  • Saves energy through Demand Control Ventilation (DCV)
  • Remote sensor option provides dual gas monitoring (standalone version only)

Advanced sensing technology

  • Capable of detecting CO, NO2, O2, H2, H2S, CH4, C3H8 (sensors sold separately)
  • Advanced electrochemical (for toxic gases) and catalytic bead (for combustible gases) sensor performance
  • Uses patented Reflex® and smart cartridge technologies (cartridges sold separately)

Certifications

  • Intertek classified to: UL 61010-1; and CSA C22.2 No. 61010-1-04
  • COLA (City of Los Angeles) approved for carbon monoxide detection in commercial buildings and parking garages

Applications

  • Parking structure
  • Loading dock transport terminal
  • Golf cart maintenance
  • Battery charging area
  • Maintenance garage
  • Hospital/ambulance bay
  • Fire/police station
  • Boiler room
  • Car wash
  • Battery charging rooms
  • H2 and hydrogen tanks
  • Commercial kitchen C3H8
  • Indoor stadium/arena

BW E3SA Specifications

Uses Wall mounted gas detector for monitoring carbon monoxide (CO), nitrogen dioxide (NO2), oxygen (O2), methane (CH4), hydrogen (H2), hydrogen sulfide (H2S), and propane (C3H8), installed as a standalone device with single-gas or dual-gas monitoring.
Detection Ranges and Alarm Levels CO (Carbon monoxide):
Resolution 1 ppm
Range: 0 to 250 ppm
Alarm A: 25 ppm
Alarm B: 100 ppm
Alarm C: 225 ppm

H2S (Hydrogen sulfide):
Resolution: 0.1 ppm
Range: 0 to 50 ppm
Alarm A: 10 ppm
Alarm B: 15 ppm
Alarm C: 20 ppm

NO2 (Nitrogen dioxide):
Resolution: 0.1 ppm
Range: 0 to 10 ppm
Alarm A: 0.7 ppm
Alarm B: 2 ppm
Alarm C: 9 ppm

O2 (Oxygen): Resolution: 0.1% volume
Range: 0 to 25% volume
Alarm A: 19.5% volume
Alarm B: 22% volume
Alarm C: 22.5% volume

H2 (Hydrogen):
Resolution: 0.5% LEL
Range: 0 to 100% LEL
Alarm A: 25% LEL
Alarm B: 50% LEL
Alarm C: 90% LEL

CH4 (Methane):
Resolution: 0.5% LEL
Range: 0 to 100% LEL
Alarm A: 25% LEL
Alarm B: 50% LEL
Alarm C: 90% LEL

C3H8 (Propane):
Resolution: 0.5% LEL
Range: 0 to 100% LEL
Alarm A: 25% LEL
Alarm B: 50% LEL
Alarm C: 90% LEL
Accuracy ±3% of full scale at 77°F (25°C)
Display 8 character, 2 line backlit LCD
Visual Indicators Green LED: Power
Amber LED 1: Alarm/fault
Amber LED 2: Alarm/fault
Audible Alarm >85 dBA at 10' (3 m)
Response Time T90 < 50 seconds
With ECLAB T90 < 240 seconds
Sensor Type Electrochemical cell (CO, NO2, H2S, O2); catalytic (CH4, H2, C3H8)
Relay Output 2 DPDT relays, 5 A at 250 VAC; 5 A at 30 V DC
Communications 4-20 mA
Operating Environment Commercial, indoor, extreme temperature environments
Operating Temperature H2S, NO2, O2, CH4, H2, C3H8: -40 to 122°F (-40 to 50°C)
CO: -4 to 122°F (-20 to 50°C)
Power Requirement 24 V AC nominal (17 to 27 VAC), 50/60 Hz, 0.35 A; 24 V DC nominal (20 to 38 V DC); with remote sensor: 7 W maximum
Enclosure Polycarbonate
Certification CSA C22.2 No. 61010-1, UL 61010-1; FCC part 15; ICES-003 issue 4; ISO 9001-2008
Dimensions 8.09 x 5.87 x 2.65" (20.56 x 14.90 x 6.72 cm)
Remote sensor: 1.36 x 1.75 x 2.56"(3.5 x 4.5 x 6.5 cm)
Click here for complete specifications on the BW E3SA

What's included with the BW E3SA

  • Toxic and Combustible Gas Monitor with Wall Mount
  • One-Year Warranty

Ask a question about Honeywell E3SA E3Point Toxic and Combustible Gas Monitor with wall mount, analog, 24 V AC/V DC

Customer Reviews for the BW E3SA

BW E3SA Offers

Capable of detecting CO, NO2, O2, H2, H2S, CH4, and C3H8 gases (sensors sold separately), this gas monitor that features an intelligent design to reduce the cost of ownership while increasing the flexibility of the application. In addition, this monitor can also operate with existing controller-based gas monitoring systems and wired-wireless gas monitoring system components.

Features

  • Versatile communications: Couple with 301C to log data and daisy-chain up to 96 toxic and combustible gas monitors
  • Electrical certification: Canada (CSA C22.2 No. 61010-1) and US (ANSI/UL 61010-1)
  • Ergonomic features built into this monitor include a hinged door for maintenance ease
  • Efficient operations: Smart sensor design, extreme temperature range, etc. optimize building performance
  • Energy saving: On-demand ventilation controls energy use
  • Economical value: Reduces cost of installation, operation and maintenance
  • Standalone dual-gas sensor operation: Economical application adds option of a second (remote) sensor for dual gas monitoring and two on-board relays can activate ventilation or strobes
  • Complete toxic and combustible gas detection system with onboard sounder

Reflex® keeps you safer

This patented Reflex® technology adds this extra degree of precision and diligence to sensor monitoring to make doubly sure you're safe. Reflex bounces electrical signals into this monitor's electrochemical sensor cell at regular intervals, a form of electronic bump testing and continuous monitoring of cell response.

Standalone single-sensor operation

A low-cost application for buildings with minimal gas monitoring requirements typical of a small facility. Offers easy installation, commissioning and operation. Two on-board relays can activate fan or strobe.

Plug-n-play ease

This monitors plug-n-play sensor (sold separately) is factory calibrated and works out of the box. Upon installation, this monitor automatically configures for quick operation. You benefit from easier installation and maintenance, and greater adaptability to changing building and safety requirements.

Flexible operation

  • Comes in standalone or standalone with remote (dual gas mode)
  • Connects to analog system
  • Wall mount
  • Factory-calibrated cartridges (sold separately)

Cost-effective

  • Saves energy through Demand Control Ventilation (DCV)
  • Remote sensor option provides dual gas monitoring (standalone version only)

Advanced sensing technology

  • Capable of detecting CO, NO2, O2, H2, H2S, CH4, C3H8 (sensors sold separately)
  • Advanced electrochemical (for toxic gases) and catalytic bead (for combustible gases) sensor performance
  • Uses patented Reflex® and smart cartridge technologies (cartridges sold separately)

Certifications

  • Intertek classified to: UL 61010-1; and CSA C22.2 No. 61010-1-04
  • COLA (City of Los Angeles) approved for carbon monoxide detection in commercial buildings and parking garages

Applications

  • Parking structure
  • Loading dock transport terminal
  • Golf cart maintenance
  • Battery charging area
  • Maintenance garage
  • Hospital/ambulance bay
  • Fire/police station
  • Boiler room
  • Car wash
  • Battery charging rooms
  • H2 and hydrogen tanks
  • Commercial kitchen C3H8
  • Indoor stadium/arena

BW E3SA Specifications

Uses Wall mounted gas detector for monitoring carbon monoxide (CO), nitrogen dioxide (NO2), oxygen (O2), methane (CH4), hydrogen (H2), hydrogen sulfide (H2S), and propane (C3H8), installed as a standalone device with single-gas or dual-gas monitoring.
Detection Ranges and Alarm Levels CO (Carbon monoxide):
Resolution 1 ppm
Range: 0 to 250 ppm
Alarm A: 25 ppm
Alarm B: 100 ppm
Alarm C: 225 ppm

H2S (Hydrogen sulfide):
Resolution: 0.1 ppm
Range: 0 to 50 ppm
Alarm A: 10 ppm
Alarm B: 15 ppm
Alarm C: 20 ppm

NO2 (Nitrogen dioxide):
Resolution: 0.1 ppm
Range: 0 to 10 ppm
Alarm A: 0.7 ppm
Alarm B: 2 ppm
Alarm C: 9 ppm

O2 (Oxygen): Resolution: 0.1% volume
Range: 0 to 25% volume
Alarm A: 19.5% volume
Alarm B: 22% volume
Alarm C: 22.5% volume

H2 (Hydrogen):
Resolution: 0.5% LEL
Range: 0 to 100% LEL
Alarm A: 25% LEL
Alarm B: 50% LEL
Alarm C: 90% LEL

CH4 (Methane):
Resolution: 0.5% LEL
Range: 0 to 100% LEL
Alarm A: 25% LEL
Alarm B: 50% LEL
Alarm C: 90% LEL

C3H8 (Propane):
Resolution: 0.5% LEL
Range: 0 to 100% LEL
Alarm A: 25% LEL
Alarm B: 50% LEL
Alarm C: 90% LEL
Accuracy ±3% of full scale at 77°F (25°C)
Display 8 character, 2 line backlit LCD
Visual Indicators Green LED: Power
Amber LED 1: Alarm/fault
Amber LED 2: Alarm/fault
Audible Alarm >85 dBA at 10' (3 m)
Response Time T90 < 50 seconds
With ECLAB T90 < 240 seconds
Sensor Type Electrochemical cell (CO, NO2, H2S, O2); catalytic (CH4, H2, C3H8)
Relay Output 2 DPDT relays, 5 A at 250 VAC; 5 A at 30 V DC
Communications 4-20 mA
Operating Environment Commercial, indoor, extreme temperature environments
Operating Temperature H2S, NO2, O2, CH4, H2, C3H8: -40 to 122°F (-40 to 50°C)
CO: -4 to 122°F (-20 to 50°C)
Power Requirement 24 V AC nominal (17 to 27 VAC), 50/60 Hz, 0.35 A; 24 V DC nominal (20 to 38 V DC); with remote sensor: 7 W maximum
Enclosure Polycarbonate
Certification CSA C22.2 No. 61010-1, UL 61010-1; FCC part 15; ICES-003 issue 4; ISO 9001-2008
Dimensions 8.09 x 5.87 x 2.65" (20.56 x 14.90 x 6.72 cm)
Remote sensor: 1.36 x 1.75 x 2.56"(3.5 x 4.5 x 6.5 cm)
Click here for complete specifications on the BW E3SA

What's included with the BW E3SA

  • Toxic and Combustible Gas Monitor with Wall Mount
  • One-Year Warranty

Ask a question about Honeywell E3SA E3Point Toxic and Combustible Gas Monitor with wall mount, analog, 24 V AC/V DC

Customer Reviews for the BW E3SA

More BW Products

Find the right sensor with our sensor selection tool