Customer Reviews

BW MCXL-XWH0-Y-NA GasAlertMicroClip XL 3-Gas Personal Gas Detector, %LEL, O2, H2S

Model: MCXL-XWH0-Y-NA

BW MCXL-XWH0-Y-NA GasAlertMicroClip XL 3-Gas Personal Gas Detector, %LEL, O<sub>2</sub>, H<sub>2</sub>S-


Downloads: datasheet

BW MCXL-XWH0-Y-NA GasAlertMicroClip XL 3-Gas Personal Gas Detector, %LEL, O2, H2S

Model: MCXL-XWH0-Y-NA

This personal gas detector alerts users of dangerous levels of Hydrogen Sulfide, Oxygen, and Combustible Gasses in their work area. The simple one button operation minimizes the need for training and gets workers on the job faster. Extended 18 hour battery run time keeps workers safe for longer. Beeping alone while working in a loud environment might not always be enough but with the visible flashing green IntelliFlash™ workers are notified of the dangers.

This personal gas detector alerts users of dangerous levels of Hydrogen Sulfide, Oxygen, and Combustible Gasses in their work area. The simple one button operation minimizes the need for training and gets workers on the job faster. Extended 18 hour battery run time keeps workers safe for longer. Beeping alone while working in a loud environment might not always be enough but with the visible flashing green IntelliFlash™ workers are notified of the dangers.

Sale Price $400.81 USD
Regular Price $538.00 USD
Availability 2 to 3 Weeks
Quantity

Add In-House Traceable Calibration to your MCXL-XWH0-Y-NA

Add In-House Traceable Calibration to your MCXL-XWH0-Y-NA


BW MCXL-XWH0-Y-NA Offers

Designed for enhanced battery operation and improved functionality in cold weather environments. For simple, cost-effective management of your records, calibration and bump testing, choose BW's MicroDock II automatic test and calibration system and Fleet Manager II software.

Features

  • Designed for cold weather performance
  • IntelliFlash verifies operation and compliance to both the user and supervisor
  • Tamper-proof, one button operation
  • Powered by a rechargeable lithium polymer battery
  • Continuous LCD shows real-time gas concentrations
  • Compact and lightweight design makes it comfortable to wear
  • Water-resistant
  • Simple automatic calibration procedure; compatible with BW MicroDock II automatic test and calibration station
  • Full function self-test of sensor, battery status, circuit integrity and audible/visual alarms on start up
  • Bright wide-angled visual alarm bars
  • Built-in concussion-proof boot
  • Multi-language support in English, French, German, Spanish and Portuguese
  • Conveniently manage your fleet using Fleet Manager II

Confined Space Kit Available
The MicroClip XL can also be used in a confined space kit. A confined space can represent a risk for the health and safety of anyone who enters, because it has restricted entrance and exit and the possibility of dangerous substances in the atmosphere. The air within the confined space should be tested from outside before entry. A trained worker should use remote probes and sampling lines with properly calibrated and maintained equipment to verify that oxygen content is within safe limits and that a hazardous atmosphere is not present.

Software
Data storage and analysis has never been so simple. With the same look and feel as Fleet Manager, Fleet Manager II allows users to download information directly from BW instruments or the MicroDock II.

With improved functionality, users can...

  • Automatically create accurate and user-friendly reports
  • Easily sort, format and graph data as well as view history
  • Archive and share data easily, including databases
  • Download and manage calibration and bump check records as well as datalogged information onto any PC

BW MCXL-XWH0-Y-NA Specifications

Hydrogen Sulfide (H2S)
Range 0 to 100ppm
Resolution 1ppm
Oxygen (O2)
Range 0 to 100ppm
Resolution 0.1%
Combustible Gases
Range 0 to 100%LEL
0 to 5.0%v/v
Resolution 1%
0.1%
General Specifications
Size 4.4 x 2.4 x 1.2" (11.3 x 6.0 x 3.1cm)
Weight 6.7oz (190g)
Temperature -4 to 122°F (-20 to 50°C)
Humidity 0 to 95% RH (non-condensing)
Ratings EMI/RFI: Complies with EMC Directive 2004/108/EC IP 66
Certifications and Approvals Class I, Div. 1, Gr. A, B, C, D
ATEX: II 1 G
Ex ia IIC T4 Ga
IECEx: Ex ia IIC T4 Ga
European Conformity
Click here for complete specifications on the BW MCXL-XWH0-Y-NA

What's included with the BW GasAlertMicroClip XL

  • GasAlertMicroClip XL
  • Rechargeable Battery
  • Wall Outlet Charging Adaptor
  • Calibration / Test Cap and Hose
  • Manual
  • Multi-Language CD Manual

How to Select the Right Gas Detection Solution

by Don Galman

There are many gas detection products on the market that might appear to be the same, but a closer inspection of specification, functionality and features reveals major differences in what products can do and the potential value they can offer. Similarly, individual applications are also unique in their respective designs, needs and processes undertaken.

Know your site risks

Before beginning to consider gas detection equipment, a risk assessment needs to be conducted. Any company employing staff has the obligation to conduct risk assessments to identify potential hazards and these can include potential gas, vapor or Oxygen deficiency risks. If gas hazards are identified, gas detection is applicable as a risk reduction method.

Identifying the prime objective

Depending on the processes being undertaken and the gases being detected, remote or off-site alarm notification plus event data logging/reporting may also be required for Health and Safety management records. Another factor impacting on the need for enhanced reporting functions might be regulatory compliance or a condition of insurance.

Ask the right questions

Having identified the primary objective, the suitable equipment is selected by asking a number of key questions. These fall into three broad categories:

  • The gases to be detected and where they may come from
  • The location and environmental conditions where detection is to take place
  • The ease of use for operators and routine servicing personnel
Identify the gases to be detected and where they may come from

The gases to be detected should be identified by the risk assessment, however experienced gas detection equipment manufacturers and their approved distributors are often able to help in this process, based on their experience of similar applications. However, it is important to remember that it is the end-user’s responsibility to identify all potential hazards. It is also essential to identify the potential source of a gas release as this helps determine the number and location of detectors required for a fixed gas detection system.

Consider the environmental conditions

The performance, accuracy and reliability of any gas detection equipment will be affected by the environmental conditions it is subjected to. Temperature, humidity and pressure levels at the location all have a direct bearing on the type of equipment that should be selected. Additional factors such as potential variations resulting from a production process itself, diurnal/nocturnal fluctuations and seasonal changes may also affect the type of device which is suitable.

Understand product functionality

The next area of consideration relates to additional product functionality. Aspects like wiring configuration are important, especially when retro-fitting into an existing application. If the apparatus is being integrated into a separate safety system, certain communication protocols may also be required such as HART®, Lonworks or Modbus®. Consideration will also need to be given regarding the requirement for local displays on transmitter units and local configuration of the unit and gas displays may also be a useful addition.

Measure the ease of use for operators and routine servicing personnel

Routine maintenance is another important consideration. Some gases and vapors can be detected with a number of different sensing technologies, e.g. Hydrocarbon gases with catalytic beads or Non-dispersive Infrared NDIR. Catalytic beads do not provide fail-to-safety operation and therefore can require a high frequency of routine maintenance, however NDIR based solutions tend to have a higher initial purchase price, but may require less routine maintenance. In-house resource to undertake such routine maintenance needs to be identified and in the absence of such a resource, budgeting for third party maintenance is an important factor in selecting the right equipment.


Need Help Selecting the Right Solution?

If you have questions about any of our gas detection products or services, please don’t hesitate to contact us. Whether you need a hand finding a new product or need help with your current system, just ask our team of Factory Trained Experts.


comments powered by Disqus

GasAlert MicroClip XL (MCXL) Expert Product Review:

The Good:

The MicroClip XL is one of the lowest priced 4-gas detectors on the market. Compact and lightweight the MCXL is easy to wear and one button operation makes it easy to use in the field. It is perfectly suited for most applications where continuous monitoring of H2S, CO, Oxygen and Combustible gases is required. In this newest version, the unit has been equipped with an enhanced battery. This enhanced battery has a typical run-time of 18 hours and is extreme-weather tested to ensure optimal operation in harsh environments. As normal, battery runtime depletes in cold weather; but the testing on this new battery proves a minimum of 12 hours at 4°F/-20°C, even after 2 years of instrument life (this 12 hour guarantee is backed up by the units warranty). For those upgrading from the MicroClip XT to the new MicroClip XL, all the accessories, docking station modules and sensors are the same so there is no need to purchase new accessories to work with the new XL model.


The Bad:

The unit has a rechargeable battery with extended life-span, but because the battery is fused to the unit's main PCB board it can only be replaced at the factory and some authorized service centers. So the swapping out of batteries in the field is not possible.


The Bottom Line:

At an affordable price the MicroClip XL is ideal for many applications, especially for those working longer shifts or for use in cold weather, and is easy to use and maintain.


Full Review:

A new version of the well-known GasAlert MicroClip unit, the GasAlert MicroClip XL is an ideal choice for anyone wanting continuous protection in an inexpensive 4-gas detector. It is a good fit in virtually any application where toxic and combustible gases are a concern, such as Oil & Gas, Utilities, Municipalities, Refineries, Steel Mills, Pulp, Paper and more.

The enhanced battery makes it ideal for those working longer shifts or in cold weather locations. The XL models have more battery power than ever, but you can't tell the difference in size or weight.

Regular maintenance is required on this model in the form of frequent calibrations. Bump Tests can also be performed on the unit depending on personal preference or site safety regulations. The built-in concussion proof boot provides excellent protection against accidental bumps, scratches and damage; and it is water-proof, with an IP rating of 67 it can be submerged in water up to 1 m deep for 30 minutes.

The real-time gas concentration is displayed continuously on the LCD so you will always know the current levels, even when the unit is not in alarm. The unit has a built in Datalogging feature, enabling you to retrieve a detailed and accurate history of conditions and unit maintenance if needed. Calibrating the unit is required every 180 days by factory default but is quick and easy to perform; the procedure can be done in the field and only takes about 2 minutes to perform, and all you will require is a cylinder of calibration gas and a regulator. It is also compatible with the BW MicroDock II calibration and bump test station for those who wish to use a more hands-free, automated, calibration and bump test procedure.

How to: Calibrate a BW Gas Detector

How to: Bump Test a BW Gas Detector

Meet Shauna Park: Our Gas Detection Expert

Click on a category to view a selection of compatible accessories with the BW MCXL-XWH0-Y-NA GasAlertMicroClip XL 3-Gas Personal Gas Detector, %LEL, O2, H2S.

BW SR-X2V Replacement Oxygen Sensor for BW Multiple Gas Detectors, O2 SR-X2V
Replacement oxygen (O2) sensor for BW Gas Detectors.




BW SR-W-MP75C Replacement MICROpeL Combustible Sensor For GasAlert Detectors, LEL SR-W-MP75C
Replacement MICROpeL combustible (LEL) sensor for the GasAlertMicroClip XT or GasAlertMax XT II series of BW gas detectors.




BW SR-H-MC Replacement MICROceL Hydrogen Sulfide Sensor for GasAlert MicroClip XT & GasAlert Max XT II, H2 SR-H-MC
Replacement MICROceL hydrogen sulfide (H2S) sensor for the GasAlert MicroClip XT or GasAlert Max XT II series of BW gas detectors.




BW SR-M-MC Replacement MICROceL Carbon Monoxide Sensor for GasAlert MicroClip XT & GasAlert Max XT II, CO SR-M-MC
Replacement MICROceL carbon monoxide (CO) sensor for the GasAlert MicroClip XT or GasAlert Max XT II series of BW gas detectors.




BW SR-W-MC-DUM Dummy Sensor for Combustible Sensor Location for GasAlertMicroClip XT & GasAlertMax XT II, LEL SR-W-MC-DUM
Dummy sensor for combustible (LEL) sensor locations. Please note that this sensor has no detection abilities and will not put the unit into alarm. It is only for training or long term storage of a unit.




BW SR-DUMM1 Dummy Sensor for Oxygen Sensor Location for GasAlertMicroClip XT, O2 SR-DUMM1
Dummy sensor for oxygen (O2) sensor location for GasAlertMicroClip XT series of BW gas detectors. Please note that this sensor has no detection abilities and will not put the unit into alarm. It is only for training or long term storage of a unit.




BW SR-TOX-MC-DUM Dummy Sensor for Toxic Sensor Locations for GasAlertMicroClip XT & GasAlertMaxXT II SR-TOX-MC-DUM
Dummy sensor for toxic sensor locations. Please note that this sensor has no detection abilities and will not put the unit into alarm. It is only for training or long term storage of a unit.




BW MC-CK-DL GasAlertMicroClip Deluxe Confined Space Kit MC-CK-DL
Use the Confined Space Kit with a BW GasAlert Gas Detector to detect gas in tight spaces. The included IR Connectivity Kit can be used to transmit data from the Gas Detector to a PC. The included Regulator can be used to control the flow of gas at up to 0.5 liters per minute (LPM).
Detector, calibration gas and motorized sampling pump sold separately.




BW MC-CK-CC Carrying Case for GasAlertMicroClip XT MC-CK-CC
BW MC-CK-CC Carrying Case for use with the GasAlertMicroClip XT, with foam and lid insert from confined space kit. Dimensions: 18 x 13 x 6".
Note: Detector, calibration gas and motorized sampling pump sold separately.








BW GA-LY-1 Short Strap for GasAlert, 6in (15.2cm) GA-LY-1
The short strap (6 in. / 15.2 cm) facilitates the attachment of your gas detector to your clothing or personal protective equipment (PPE). The smaller loop attaches to buttons or other fasteners.





BW GA-CH-2 Chest Harness for GasAlert GA-CH-2
For use with GasAlert gas detectors.
Note: Unit not included.




BW MC2-C01-MC5 Multi-Unit Cradle Charger for GasAlertMicroClip XT, 5-Units MC2-C01-MC5
Using adaptors other than those supplied may cause damage to GasAlertMicroClip XT units in the charger. Charging status can be monitored on the detectors' LCD. Wall or table mountable, the multi-unit charger ships with a power adaptor. Simply slide detectors or batteries into the charger and wait for the battery icon on the LCD to show the battery is fully charged or the LED on the battery to turn green.
Note: Units not included.




BW GA-VPA-1 Vehicle Power Adaptor for GasAlertMicroClip XT & XL, GasAlertQuattro & GasAlertMax XT II GA-VPA-1
Vehicle power adaptor, compatible with GasAlert Micro Clip XT and XL, GasAlert Quattro, and GasAlert Max XT II models.




BW GA-PA-3 12-24 VDC Direct-Wire Power Adaptor for GasAlert XT, XT II & Quattro, V DC GA-PA-3
For use with the GasAlert XT, XT II & Quattro. Connect directly to a 12V or 24V power system with the 12-24 V DC Direct-Wire Power Adaptor. Simply connect the adaptor to the detector's charging/IR interface.




BW GA-PA-1-NA Replacement Power Adaptor for GasAlert GA-PA-1-NA
GA-PA-1-NA BW Technologies 120VAC North America Replacement Power Adapter / Charger.




BW DOCK2-2-1C1P-00-G MicroDock II Automatic Test & Calibration Station with GasAlertMicroClip Docking Module, Charging with Power Supply DOCK2-2-1C1P-00-G
Manage the calibration and bump testing on your portable gas detector in the most cost effective way, sort through the data collected and charge your units. Automated testing and calibrating system, automated management of event logs, calibration logs, etc and automated verification of alarm set points allows you to keep working without missing a notification.




BW DOCK2-2-1P-00-G MicroDock II Automatic Test & Calibration Station with GasAlertMicroClip Docking Module, Charging with No Power Supply DOCK2-2-1P-00-G
Manage the calibration and bump testing on your portable gas detector in the most cost effective way, sort through the data collected and charge your units. Automated testing and calibrating system, automated management of event logs, calibration logs, etc and automated verification of alarm set points allows you to keep working without missing a notification.




BW DOCK2-2-1C1P-00-G GasAlertMicroClip XT module for MicroDock II Automatic Test & Calibration Station, Charging with power supply and 2 inlets DOCK2-0-1C1P-00-G
Plug the GasAlertMicroClip XT docking module into the MicroDock II Automatic Test & Calibration Station and start managing it.




BW DOCK2-0-1P-00-G GasAlertMicroClip XT module for MicroDock II Automatic Test & Calibration Station, charging with no power supply and 2 inlets DOCK2-0-1P-00-G
Plug the GasAlertMicroClip XT docking module into the MicroDock II Automatic Test & Calibration Station and start managing it.




Customer Reviews for the BW MCXL-XWH0-Y-NA

Ask a question about BW MCXL-XWH0-Y-NA GasAlertMicroClip XL 3-Gas Personal Gas Detector, %LEL, O2, H2S

comments powered by Disqus

BW MCXL-XWH0-Y-NA Offers

Designed for enhanced battery operation and improved functionality in cold weather environments. For simple, cost-effective management of your records, calibration and bump testing, choose BW's MicroDock II automatic test and calibration system and Fleet Manager II software.

Features

  • Designed for cold weather performance
  • IntelliFlash verifies operation and compliance to both the user and supervisor
  • Tamper-proof, one button operation
  • Powered by a rechargeable lithium polymer battery
  • Continuous LCD shows real-time gas concentrations
  • Compact and lightweight design makes it comfortable to wear
  • Water-resistant
  • Simple automatic calibration procedure; compatible with BW MicroDock II automatic test and calibration station
  • Full function self-test of sensor, battery status, circuit integrity and audible/visual alarms on start up
  • Bright wide-angled visual alarm bars
  • Built-in concussion-proof boot
  • Multi-language support in English, French, German, Spanish and Portuguese
  • Conveniently manage your fleet using Fleet Manager II

Confined Space Kit Available
The MicroClip XL can also be used in a confined space kit. A confined space can represent a risk for the health and safety of anyone who enters, because it has restricted entrance and exit and the possibility of dangerous substances in the atmosphere. The air within the confined space should be tested from outside before entry. A trained worker should use remote probes and sampling lines with properly calibrated and maintained equipment to verify that oxygen content is within safe limits and that a hazardous atmosphere is not present.

Software
Data storage and analysis has never been so simple. With the same look and feel as Fleet Manager, Fleet Manager II allows users to download information directly from BW instruments or the MicroDock II.

With improved functionality, users can...

  • Automatically create accurate and user-friendly reports
  • Easily sort, format and graph data as well as view history
  • Archive and share data easily, including databases
  • Download and manage calibration and bump check records as well as datalogged information onto any PC

BW MCXL-XWH0-Y-NA Specifications

Hydrogen Sulfide (H2S)
Range 0 to 100ppm
Resolution 1ppm
Oxygen (O2)
Range 0 to 100ppm
Resolution 0.1%
Combustible Gases
Range 0 to 100%LEL
0 to 5.0%v/v
Resolution 1%
0.1%
General Specifications
Size 4.4 x 2.4 x 1.2" (11.3 x 6.0 x 3.1cm)
Weight 6.7oz (190g)
Temperature -4 to 122°F (-20 to 50°C)
Humidity 0 to 95% RH (non-condensing)
Ratings EMI/RFI: Complies with EMC Directive 2004/108/EC IP 66
Certifications and Approvals Class I, Div. 1, Gr. A, B, C, D
ATEX: II 1 G
Ex ia IIC T4 Ga
IECEx: Ex ia IIC T4 Ga
European Conformity
Click here for complete specifications on the BW MCXL-XWH0-Y-NA

What's included with the BW GasAlertMicroClip XL

  • GasAlertMicroClip XL
  • Rechargeable Battery
  • Wall Outlet Charging Adaptor
  • Calibration / Test Cap and Hose
  • Manual
  • Multi-Language CD Manual

How to Select the Right Gas Detection Solution

by Don Galman

There are many gas detection products on the market that might appear to be the same, but a closer inspection of specification, functionality and features reveals major differences in what products can do and the potential value they can offer. Similarly, individual applications are also unique in their respective designs, needs and processes undertaken.

Know your site risks

Before beginning to consider gas detection equipment, a risk assessment needs to be conducted. Any company employing staff has the obligation to conduct risk assessments to identify potential hazards and these can include potential gas, vapor or Oxygen deficiency risks. If gas hazards are identified, gas detection is applicable as a risk reduction method.

Identifying the prime objective

Depending on the processes being undertaken and the gases being detected, remote or off-site alarm notification plus event data logging/reporting may also be required for Health and Safety management records. Another factor impacting on the need for enhanced reporting functions might be regulatory compliance or a condition of insurance.

Ask the right questions

Having identified the primary objective, the suitable equipment is selected by asking a number of key questions. These fall into three broad categories:

  • The gases to be detected and where they may come from
  • The location and environmental conditions where detection is to take place
  • The ease of use for operators and routine servicing personnel
Identify the gases to be detected and where they may come from

The gases to be detected should be identified by the risk assessment, however experienced gas detection equipment manufacturers and their approved distributors are often able to help in this process, based on their experience of similar applications. However, it is important to remember that it is the end-user’s responsibility to identify all potential hazards. It is also essential to identify the potential source of a gas release as this helps determine the number and location of detectors required for a fixed gas detection system.

Consider the environmental conditions

The performance, accuracy and reliability of any gas detection equipment will be affected by the environmental conditions it is subjected to. Temperature, humidity and pressure levels at the location all have a direct bearing on the type of equipment that should be selected. Additional factors such as potential variations resulting from a production process itself, diurnal/nocturnal fluctuations and seasonal changes may also affect the type of device which is suitable.

Understand product functionality

The next area of consideration relates to additional product functionality. Aspects like wiring configuration are important, especially when retro-fitting into an existing application. If the apparatus is being integrated into a separate safety system, certain communication protocols may also be required such as HART®, Lonworks or Modbus®. Consideration will also need to be given regarding the requirement for local displays on transmitter units and local configuration of the unit and gas displays may also be a useful addition.

Measure the ease of use for operators and routine servicing personnel

Routine maintenance is another important consideration. Some gases and vapors can be detected with a number of different sensing technologies, e.g. Hydrocarbon gases with catalytic beads or Non-dispersive Infrared NDIR. Catalytic beads do not provide fail-to-safety operation and therefore can require a high frequency of routine maintenance, however NDIR based solutions tend to have a higher initial purchase price, but may require less routine maintenance. In-house resource to undertake such routine maintenance needs to be identified and in the absence of such a resource, budgeting for third party maintenance is an important factor in selecting the right equipment.


Need Help Selecting the Right Solution?

If you have questions about any of our gas detection products or services, please don’t hesitate to contact us. Whether you need a hand finding a new product or need help with your current system, just ask our team of Factory Trained Experts.


comments powered by Disqus

GasAlert MicroClip XL (MCXL) Expert Product Review:

The Good:

The MicroClip XL is one of the lowest priced 4-gas detectors on the market. Compact and lightweight the MCXL is easy to wear and one button operation makes it easy to use in the field. It is perfectly suited for most applications where continuous monitoring of H2S, CO, Oxygen and Combustible gases is required. In this newest version, the unit has been equipped with an enhanced battery. This enhanced battery has a typical run-time of 18 hours and is extreme-weather tested to ensure optimal operation in harsh environments. As normal, battery runtime depletes in cold weather; but the testing on this new battery proves a minimum of 12 hours at 4°F/-20°C, even after 2 years of instrument life (this 12 hour guarantee is backed up by the units warranty). For those upgrading from the MicroClip XT to the new MicroClip XL, all the accessories, docking station modules and sensors are the same so there is no need to purchase new accessories to work with the new XL model.


The Bad:

The unit has a rechargeable battery with extended life-span, but because the battery is fused to the unit's main PCB board it can only be replaced at the factory and some authorized service centers. So the swapping out of batteries in the field is not possible.


The Bottom Line:

At an affordable price the MicroClip XL is ideal for many applications, especially for those working longer shifts or for use in cold weather, and is easy to use and maintain.


Full Review:

A new version of the well-known GasAlert MicroClip unit, the GasAlert MicroClip XL is an ideal choice for anyone wanting continuous protection in an inexpensive 4-gas detector. It is a good fit in virtually any application where toxic and combustible gases are a concern, such as Oil & Gas, Utilities, Municipalities, Refineries, Steel Mills, Pulp, Paper and more.

The enhanced battery makes it ideal for those working longer shifts or in cold weather locations. The XL models have more battery power than ever, but you can't tell the difference in size or weight.

Regular maintenance is required on this model in the form of frequent calibrations. Bump Tests can also be performed on the unit depending on personal preference or site safety regulations. The built-in concussion proof boot provides excellent protection against accidental bumps, scratches and damage; and it is water-proof, with an IP rating of 67 it can be submerged in water up to 1 m deep for 30 minutes.

The real-time gas concentration is displayed continuously on the LCD so you will always know the current levels, even when the unit is not in alarm. The unit has a built in Datalogging feature, enabling you to retrieve a detailed and accurate history of conditions and unit maintenance if needed. Calibrating the unit is required every 180 days by factory default but is quick and easy to perform; the procedure can be done in the field and only takes about 2 minutes to perform, and all you will require is a cylinder of calibration gas and a regulator. It is also compatible with the BW MicroDock II calibration and bump test station for those who wish to use a more hands-free, automated, calibration and bump test procedure.

How to: Calibrate a BW Gas Detector

How to: Bump Test a BW Gas Detector

Meet Shauna Park: Our Gas Detection Expert

Click on a category to view a selection of compatible accessories with the BW MCXL-XWH0-Y-NA GasAlertMicroClip XL 3-Gas Personal Gas Detector, %LEL, O2, H2S.

BW SR-X2V Replacement Oxygen Sensor for BW Multiple Gas Detectors, O2 SR-X2V
Replacement oxygen (O2) sensor for BW Gas Detectors.




BW SR-W-MP75C Replacement MICROpeL Combustible Sensor For GasAlert Detectors, LEL SR-W-MP75C
Replacement MICROpeL combustible (LEL) sensor for the GasAlertMicroClip XT or GasAlertMax XT II series of BW gas detectors.




BW SR-H-MC Replacement MICROceL Hydrogen Sulfide Sensor for GasAlert MicroClip XT & GasAlert Max XT II, H2 SR-H-MC
Replacement MICROceL hydrogen sulfide (H2S) sensor for the GasAlert MicroClip XT or GasAlert Max XT II series of BW gas detectors.




BW SR-M-MC Replacement MICROceL Carbon Monoxide Sensor for GasAlert MicroClip XT & GasAlert Max XT II, CO SR-M-MC
Replacement MICROceL carbon monoxide (CO) sensor for the GasAlert MicroClip XT or GasAlert Max XT II series of BW gas detectors.




BW SR-W-MC-DUM Dummy Sensor for Combustible Sensor Location for GasAlertMicroClip XT & GasAlertMax XT II, LEL SR-W-MC-DUM
Dummy sensor for combustible (LEL) sensor locations. Please note that this sensor has no detection abilities and will not put the unit into alarm. It is only for training or long term storage of a unit.




BW SR-DUMM1 Dummy Sensor for Oxygen Sensor Location for GasAlertMicroClip XT, O2 SR-DUMM1
Dummy sensor for oxygen (O2) sensor location for GasAlertMicroClip XT series of BW gas detectors. Please note that this sensor has no detection abilities and will not put the unit into alarm. It is only for training or long term storage of a unit.




BW SR-TOX-MC-DUM Dummy Sensor for Toxic Sensor Locations for GasAlertMicroClip XT & GasAlertMaxXT II SR-TOX-MC-DUM
Dummy sensor for toxic sensor locations. Please note that this sensor has no detection abilities and will not put the unit into alarm. It is only for training or long term storage of a unit.




BW MC-CK-DL GasAlertMicroClip Deluxe Confined Space Kit MC-CK-DL
Use the Confined Space Kit with a BW GasAlert Gas Detector to detect gas in tight spaces. The included IR Connectivity Kit can be used to transmit data from the Gas Detector to a PC. The included Regulator can be used to control the flow of gas at up to 0.5 liters per minute (LPM).
Detector, calibration gas and motorized sampling pump sold separately.




BW MC-CK-CC Carrying Case for GasAlertMicroClip XT MC-CK-CC
BW MC-CK-CC Carrying Case for use with the GasAlertMicroClip XT, with foam and lid insert from confined space kit. Dimensions: 18 x 13 x 6".
Note: Detector, calibration gas and motorized sampling pump sold separately.








BW GA-LY-1 Short Strap for GasAlert, 6in (15.2cm) GA-LY-1
The short strap (6 in. / 15.2 cm) facilitates the attachment of your gas detector to your clothing or personal protective equipment (PPE). The smaller loop attaches to buttons or other fasteners.





BW GA-CH-2 Chest Harness for GasAlert GA-CH-2
For use with GasAlert gas detectors.
Note: Unit not included.




BW MC2-C01-MC5 Multi-Unit Cradle Charger for GasAlertMicroClip XT, 5-Units MC2-C01-MC5
Using adaptors other than those supplied may cause damage to GasAlertMicroClip XT units in the charger. Charging status can be monitored on the detectors' LCD. Wall or table mountable, the multi-unit charger ships with a power adaptor. Simply slide detectors or batteries into the charger and wait for the battery icon on the LCD to show the battery is fully charged or the LED on the battery to turn green.
Note: Units not included.




BW GA-VPA-1 Vehicle Power Adaptor for GasAlertMicroClip XT & XL, GasAlertQuattro & GasAlertMax XT II GA-VPA-1
Vehicle power adaptor, compatible with GasAlert Micro Clip XT and XL, GasAlert Quattro, and GasAlert Max XT II models.




BW GA-PA-3 12-24 VDC Direct-Wire Power Adaptor for GasAlert XT, XT II & Quattro, V DC GA-PA-3
For use with the GasAlert XT, XT II & Quattro. Connect directly to a 12V or 24V power system with the 12-24 V DC Direct-Wire Power Adaptor. Simply connect the adaptor to the detector's charging/IR interface.




BW GA-PA-1-NA Replacement Power Adaptor for GasAlert GA-PA-1-NA
GA-PA-1-NA BW Technologies 120VAC North America Replacement Power Adapter / Charger.




BW DOCK2-2-1C1P-00-G MicroDock II Automatic Test & Calibration Station with GasAlertMicroClip Docking Module, Charging with Power Supply DOCK2-2-1C1P-00-G
Manage the calibration and bump testing on your portable gas detector in the most cost effective way, sort through the data collected and charge your units. Automated testing and calibrating system, automated management of event logs, calibration logs, etc and automated verification of alarm set points allows you to keep working without missing a notification.




BW DOCK2-2-1P-00-G MicroDock II Automatic Test & Calibration Station with GasAlertMicroClip Docking Module, Charging with No Power Supply DOCK2-2-1P-00-G
Manage the calibration and bump testing on your portable gas detector in the most cost effective way, sort through the data collected and charge your units. Automated testing and calibrating system, automated management of event logs, calibration logs, etc and automated verification of alarm set points allows you to keep working without missing a notification.




BW DOCK2-2-1C1P-00-G GasAlertMicroClip XT module for MicroDock II Automatic Test & Calibration Station, Charging with power supply and 2 inlets DOCK2-0-1C1P-00-G
Plug the GasAlertMicroClip XT docking module into the MicroDock II Automatic Test & Calibration Station and start managing it.




BW DOCK2-0-1P-00-G GasAlertMicroClip XT module for MicroDock II Automatic Test & Calibration Station, charging with no power supply and 2 inlets DOCK2-0-1P-00-G
Plug the GasAlertMicroClip XT docking module into the MicroDock II Automatic Test & Calibration Station and start managing it.




Ask a question about BW MCXL-XWH0-Y-NA GasAlertMicroClip XL 3-Gas Personal Gas Detector, %LEL, O2, H2S

Customer Reviews for the BW MCXL-XWH0-Y-NA

More BW Products

Find the right sensor with our sensor selection tool