Customer Reviews

Honeywell DX-MCLP IntelliDoX Docking Station for the MicroClip series

Model: DX-MCLP

Honeywell DX-MCLP IntelliDoX Docking Station for the MicroClip series-


Downloads: datasheet manual

Honeywell DX-MCLP IntelliDoX Docking Station for the MicroClip series

Model: DX-MCLP

Combines intuitive docking modules and device management software to provide automated instrument management for the MicroClip series multi-gas detectors - helping drive productivity, reliability, and efficiency. Set the module to do a bump test, reconfigure the detector’s high and low alarm setpoints, and more.

Combines intuitive docking modules and device management software to provide automated instrument management for the MicroClip series multi-gas detectors - helping drive productivity, reliability, and efficiency. Set the module to do a bump test, reconfigure the detector’s high and low alarm setpoints, and more.

Sale Price $2762.46 USD
Regular Price $3708.00 USD
Availability 9 to 10 Weeks
Quantity
The following item is required to funtion with your gas detector

The following item is required to funtion with your gas detector


BW DX-MCLP Offers

The Honeywell DX-MCLP IntelliDoX docking station automates bump testing and calibration for BW MicroClip series multi-gas detectors. Use Honeywell Safety Suite Device Configurator to configure compatible detector settings and manage test records. Each module has its own LCD screen, keypad and pump, allowing connected modules to perform different operations independently. USB and Ethernet connections support data transfer for instrument record-keeping.

Features

  • Automated bump testing and span calibration for compatible BW MicroClip series detectors
  • Configurable high and low detector alarm setpoints through Honeywell Safety Suite Device Configurator
  • Connect up to five modules to share power, network and gas connections
  • Independent module operation allows different tests to run at the same time
  • Built-in LCD screen and keypad for local dock settings and operation
  • USB and Ethernet interfaces for transferring test records and detector data
  • Internal memory retains transferred detector datalogs and event logs
  • Two-way infrared communication between the module and detector
  • Replaceable detector nest supports servicing and compatible device changes
  • Multi-inlet key enables connections to multiple calibration gas cylinders (Optional, Sold Separately)

Applications

  • Safety teams performing routine bump tests and calibrations on BW MicroClip detector fleets
  • Equipment managers maintaining gas detector test records and configuration settings
  • Maintenance teams organizing multi-module testing stations for workforce detector checks

BW DX-MCLP Specifications

Compatible Detectors Honeywell BW MicroClip series
Automatic Tests Functional bump test, calibration, audible alarm test and visual alarm test
Instrument And Sensor Recognition Automatic
Alarm And Calibration Parameters User-defined
Detector Communication Two-way infrared
External Interfaces 1 USB port; 1 Ethernet port
Internal Data Storage 2 GB
Real-Time Clock Date and time stamps
Instrument Management Software Honeywell Safety Suite Device Configurator; Fleet Manager II version 4.5 or higher
Connected Modules Up to 5 modules sharing power, network and gas connections
Pump Independent pump in each module
Pump Flow Rate 350 mL/min
Standard Gas Inlets 1 calibration gas inlet; 1 ambient air purge inlet
Gas Connection 1/8" (3.2 mm) sub-miniature connect (SMC) coupling
Power Supply 12 V, 8.33 A ITE power supply; supplied in the required enabler kit (Sold Separately)
Operating Environment Indoor use only; normal atmosphere free of hazardous gas
Operating Temperature 50 to 95°F (10 to 35°C)
Storage Temperature 14 to 140°F (-10 to 60°C)
Relative Humidity 10 to 90%, non-condensing
Maximum Altitude 6561' (2000 m)
Ingress Protection IP20
Enclosure Material Impact-resistant polycarbonate and acrylonitrile butadiene styrene (PC+ABS)
Dimensions 5.4 x 14.2 x 4.3" (13.8 x 36.2 x 10.9 cm), individual module
Weight 4.2 lbs (1.91 kg)
Click here for complete specifications on the BW DX-MCLP

What's included with the BW DX-MCLP

  • Docking Module
  • Factory-Installed MicroClip Detector Nest
  • Single-Inlet Key
  • Attached End Plate
  • Quick Reference Guide
  • Two-Year Warranty

Webinar: The Fundamentals of Portable Gas Detection with Honeywell


Flammable and toxic gas detection instruments are generally available in two different formats: portable (spot reading) detectors and fixed (permanently sited) monitors. Selecting which is most appropriate for a particular application depends on several factors. Including how often the area is accessed by personnel, site conditions, whether the hazard is permanent or transitory, how often testing is needed, and last but not least, the availability of finances.

We've teamed up with Honeywell for this short webinar on Portable Gas Detection, where we cover:
• Characteristics and hazards of a confined space
• The 2 main functions of portable gas detectors
• The various applications
• What to do during alarms situations
• Potential contaminants for the sensors
• Calibration versus bump-test... The difference
• Using an IntelliDoX docking station
• Maintenance, cleaning, and service
• Extreme weather conditions... What to do

Click on a category to view a selection of compatible accessories with the Honeywell DX-MCLP IntelliDoX Docking Station for the MicroClip series.

Honeywell BW DX-CASE IntelliDoX Mobile Case, standard DX-CASE
Supports one or two IntelliDoX Docking Stations and two 34 L cylinders.




Honeywell BW DX-CASE1 IntelliDoX Mobile Case, large DX-CASE1
Supports one or two IntelliDoX Docking Stations and two 58 L cylinders.




Honeywell BW DX-FILTERS IntelliDoX Filters and Hoses Kit DX-FILTERS
For use with IntelliDoX Docking Stations.




Honeywell BW DX-COVER IntelliDoX Universal End Plate DX-COVER
For use with IntelliDoX Docking Stations.




Honeywell BW DX-ARM IntelliDoX Universal Latch Arm DX-ARM
For use with IntelliDoX Docking Stations.




Honeywell BW DX-NEST-MCLP IntelliDoX Nest for the MicroClip series DX-NEST-MCLP
For use with MicroClip Multi-Gas Detectors.




Honeywell BW DX-VPA IntelliDoX Vehicle Power Adaptor DX-VPA
For use with IntelliDoX Docking Stations.




Honeywell BW DX-MI-KEY IntelliDoX Multi-Inlet Key DX-MI-KEY
For use with IntelliDoX Docking Stations.




Honeywell BW DX-SI-KEY IntelliDoX Single-Inlet Key DX-SI-KEY
For use with IntelliDoX Docking Stations.




Honeywell BW DX-STAND IntelliDoX Retractable Stand/Wall Mount DX-STAND
For use with IntelliDoX Docking Stations.




Ask a question about Honeywell DX-MCLP IntelliDoX Docking Station for the MicroClip series

Customer Reviews for the BW DX-MCLP

BW DX-MCLP Offers

The Honeywell DX-MCLP IntelliDoX docking station automates bump testing and calibration for BW MicroClip series multi-gas detectors. Use Honeywell Safety Suite Device Configurator to configure compatible detector settings and manage test records. Each module has its own LCD screen, keypad and pump, allowing connected modules to perform different operations independently. USB and Ethernet connections support data transfer for instrument record-keeping.

Features

  • Automated bump testing and span calibration for compatible BW MicroClip series detectors
  • Configurable high and low detector alarm setpoints through Honeywell Safety Suite Device Configurator
  • Connect up to five modules to share power, network and gas connections
  • Independent module operation allows different tests to run at the same time
  • Built-in LCD screen and keypad for local dock settings and operation
  • USB and Ethernet interfaces for transferring test records and detector data
  • Internal memory retains transferred detector datalogs and event logs
  • Two-way infrared communication between the module and detector
  • Replaceable detector nest supports servicing and compatible device changes
  • Multi-inlet key enables connections to multiple calibration gas cylinders (Optional, Sold Separately)

Applications

  • Safety teams performing routine bump tests and calibrations on BW MicroClip detector fleets
  • Equipment managers maintaining gas detector test records and configuration settings
  • Maintenance teams organizing multi-module testing stations for workforce detector checks

BW DX-MCLP Specifications

Compatible Detectors Honeywell BW MicroClip series
Automatic Tests Functional bump test, calibration, audible alarm test and visual alarm test
Instrument And Sensor Recognition Automatic
Alarm And Calibration Parameters User-defined
Detector Communication Two-way infrared
External Interfaces 1 USB port; 1 Ethernet port
Internal Data Storage 2 GB
Real-Time Clock Date and time stamps
Instrument Management Software Honeywell Safety Suite Device Configurator; Fleet Manager II version 4.5 or higher
Connected Modules Up to 5 modules sharing power, network and gas connections
Pump Independent pump in each module
Pump Flow Rate 350 mL/min
Standard Gas Inlets 1 calibration gas inlet; 1 ambient air purge inlet
Gas Connection 1/8" (3.2 mm) sub-miniature connect (SMC) coupling
Power Supply 12 V, 8.33 A ITE power supply; supplied in the required enabler kit (Sold Separately)
Operating Environment Indoor use only; normal atmosphere free of hazardous gas
Operating Temperature 50 to 95°F (10 to 35°C)
Storage Temperature 14 to 140°F (-10 to 60°C)
Relative Humidity 10 to 90%, non-condensing
Maximum Altitude 6561' (2000 m)
Ingress Protection IP20
Enclosure Material Impact-resistant polycarbonate and acrylonitrile butadiene styrene (PC+ABS)
Dimensions 5.4 x 14.2 x 4.3" (13.8 x 36.2 x 10.9 cm), individual module
Weight 4.2 lbs (1.91 kg)
Click here for complete specifications on the BW DX-MCLP

What's included with the BW DX-MCLP

  • Docking Module
  • Factory-Installed MicroClip Detector Nest
  • Single-Inlet Key
  • Attached End Plate
  • Quick Reference Guide
  • Two-Year Warranty

Webinar: The Fundamentals of Portable Gas Detection with Honeywell


Flammable and toxic gas detection instruments are generally available in two different formats: portable (spot reading) detectors and fixed (permanently sited) monitors. Selecting which is most appropriate for a particular application depends on several factors. Including how often the area is accessed by personnel, site conditions, whether the hazard is permanent or transitory, how often testing is needed, and last but not least, the availability of finances.

We've teamed up with Honeywell for this short webinar on Portable Gas Detection, where we cover:
• Characteristics and hazards of a confined space
• The 2 main functions of portable gas detectors
• The various applications
• What to do during alarms situations
• Potential contaminants for the sensors
• Calibration versus bump-test... The difference
• Using an IntelliDoX docking station
• Maintenance, cleaning, and service
• Extreme weather conditions... What to do

Click on a category to view a selection of compatible accessories with the Honeywell DX-MCLP IntelliDoX Docking Station for the MicroClip series.

Honeywell BW DX-CASE IntelliDoX Mobile Case, standard DX-CASE
Supports one or two IntelliDoX Docking Stations and two 34 L cylinders.




Honeywell BW DX-CASE1 IntelliDoX Mobile Case, large DX-CASE1
Supports one or two IntelliDoX Docking Stations and two 58 L cylinders.




Honeywell BW DX-FILTERS IntelliDoX Filters and Hoses Kit DX-FILTERS
For use with IntelliDoX Docking Stations.




Honeywell BW DX-COVER IntelliDoX Universal End Plate DX-COVER
For use with IntelliDoX Docking Stations.




Honeywell BW DX-ARM IntelliDoX Universal Latch Arm DX-ARM
For use with IntelliDoX Docking Stations.




Honeywell BW DX-NEST-MCLP IntelliDoX Nest for the MicroClip series DX-NEST-MCLP
For use with MicroClip Multi-Gas Detectors.




Honeywell BW DX-VPA IntelliDoX Vehicle Power Adaptor DX-VPA
For use with IntelliDoX Docking Stations.




Honeywell BW DX-MI-KEY IntelliDoX Multi-Inlet Key DX-MI-KEY
For use with IntelliDoX Docking Stations.




Honeywell BW DX-SI-KEY IntelliDoX Single-Inlet Key DX-SI-KEY
For use with IntelliDoX Docking Stations.




Honeywell BW DX-STAND IntelliDoX Retractable Stand/Wall Mount DX-STAND
For use with IntelliDoX Docking Stations.




Ask a question about Honeywell DX-MCLP IntelliDoX Docking Station for the MicroClip series

Customer Reviews for the BW DX-MCLP

More BW Products

Find the right sensor with our sensor selection tool